Human Serum, C1s Depleted

Normal human serum with C1s removed by immunoaffinity chromatography.

Specifications

Physical State:
Frozen Liquid
Storage:
-70°C or below
Complement Pathways:
Alternative pathway functional; lectin pathway not tested
Buffer:
10 mM sodium phosphate, 145 mM NaCl, pH 7.3
Preservative:
None
Filtration:
0.22 µm

Release criteria

Protein Concentration:
>50 mg/mL
Activity:
>70% of normal human serum when reconstituted with C1s (31 µg/mL)
Purity:
No C1s detectable by immunodiffusion
CH50/mL C1s-Dpl reconstituted with 31 µg C1s proenzyme/mL:
> 40 CH50/mL
APH50/mL C1s-Dpl:
> 50 APH50/mL
HBsAg:
Negative
10 more criteria Show less
Anti-HIV-I/2 plus O antibodies:
Negative
Wnv-rna:
Negative
Anti-HCV:
Negative
HCV by NAT:
Negative
HIV by NAT:
Negative
HBV by NAT:
Negative
West Nile Virus (WNV) by NAT:
Negative
Anti-Syphilis:
Negative
Anti-HBc:
Negative
Anti-HTLV-I/II:
Negative
Learn more

Product code: SHU1S-500UL

Legacy code: 34102-0.5

Custom/Bulk request
See bulk requirements
Bulk requests: more than 1 L
Unit price$149.00
Add to Quote

Lead time on this item is currently: 2-4 Weeks

Need help? Ask a Specialist Contact UsOR +1 (800) 643-3426

Product Overview

Product Types: Serum
Source: Normal Human Serum
Pooling: Pooled
Donor Sex: Mixed
Depletion Process: Immunoaffinity Chromatography
Processing Method: Affinity Depleted
Physical State: Frozen Liquid
Buffer: 10 mM sodium phosphate, 145 mM NaCl, pH 7.3
Protein Concentration: >50 mg/mL
Activity: >70% of normal human serum when reconstituted with C1s (31 µg/mL)
Complement Pathways: Alternative pathway functional; lectin pathway not tested
Purity: No C1s detectable by immunodiffusion
Preservative: None
Filtration: 0.22 µm
Application Notes: Used to assess C1s hemolytic activity in samples and to supply an alternative pathway activating system that is incapable of activating the classical complement pathway.
Testing: Serum tested negative for infectious disease per FDA guidelines.
Storage Conditions: -70°C or below
Shipping Conditions: Dry ice
Packaging: Cryovial
Expiration: 1 year from date of receipt when stored continuously at -70°C or below; avoid repeated freeze/thaw. Product quality is guaranteed to meet Pel-Freez Biologicals' specifications for this period when stored as indicated.

Product Applications

  • Hemolytic complement assay
  • Classical pathway assay
  • Alternative pathway assay
  • Assay diluent & negative matrix
  • Assay controls & calibrators
  • In vitro diagnostics
Documents & Datasheets

Certificate of Analysis

Frequently Asked Questions
What are C1q- and factor-depleted human sera used for?
Each depleted serum has a single complement component (C1q, C1r, C1s, C2 through C9, or factor B, D, H, I or P) removed, so the affected pathway stalls until that component is added back. They are used to study the role of one component, as reagents in functional complement assays, and as controls in add-back experiments.

View all frequently asked questions