Human Serum, C1q/Factor D Depleted

Normal human serum with C1q and factor D removed by immunoaffinity chromatography.

Specifications

Physical State:
Frozen Liquid
Storage:
-70°C or below
Complement Pathways:
<5% classical and alternative pathway activity
Buffer:
5 mM sodium phosphate, 145 mM NaCl, pH 7.3
Filtration:
0.22 µm

Release criteria

Protein Concentration:
>50 mg/mL
Activity:
>70% of normal human serum when reconstituted with C1q (70 µg/mL) and factor D (1.4 µg/mL)
Purity:
No C1q or factor D detectable by immunodiffusion
Learn more
Default Title

Product code: SHUQD-EA

Legacy code: 34116-1

Custom/Bulk request
See bulk requirements
Bulk requests: more than 1 L
Unit price$330.00
Add to Quote

Lead time on this item is currently: 2-4 Weeks

Need help? Ask a Specialist Contact UsOR +1 (800) 643-3426

Product Overview

Species: Human
Product Types: Serum
Source: Normal Human Serum
Pooling: Pooled
Donor Sex: Mixed
Depletion Process: Immunoaffinity Chromatography
Processing Method: Affinity Depleted
Physical State: Frozen Liquid
Buffer: 5 mM sodium phosphate, 145 mM NaCl, pH 7.3
Protein Concentration: >50 mg/mL
Activity: >70% of normal human serum when reconstituted with C1q (70 µg/mL) and factor D (1.4 µg/mL)
Complement Pathways: <5% classical and alternative pathway activity
Purity: No C1q or factor D detectable by immunodiffusion
Filtration: 0.22 µm
Application Notes: Functional classical pathway upon addition of C1q (70 µg/mL). Functional alternative pathway upon addition of factor D (1.4 µg/mL).
Testing: Serum tested negative for infectious disease per FDA guidelines.
Storage Conditions: -70°C or below
Shipping Conditions: Dry ice
Packaging: Cryovial
Expiration: 1 year from date of receipt when stored continuously at -70°C or below; avoid repeated freeze/thaw. Product quality is guaranteed to meet Pel-Freez Biologicals' specifications for this period when stored as indicated.

Product Applications

  • Hemolytic complement assay
  • Classical pathway assay
  • Alternative pathway assay
  • Assay diluent & negative matrix
  • Assay controls & calibrators
  • In vitro diagnostics
Documents & Datasheets

Certificate of Analysis

Frequently Asked Questions
What are C1q- and factor-depleted human sera used for?
Each depleted serum has a single complement component (C1q, C1r, C1s, C2 through C9, or factor B, D, H, I or P) removed, so the affected pathway stalls until that component is added back. They are used to study the role of one component, as reagents in functional complement assays, and as controls in add-back experiments.

View all frequently asked questions